Installation Instructions for 34HW–35HW IDH Max Mortise Locks
BEST ACCESS SYSTEMS
Indianapolis, Indiana
9
Installation Instructions for 34HW–35HW IDH Max Mortise Locks
Installing the lock
9 Install mortise case
1 Remove the faceplate from the mortise case.
2 Insert the mortise case into the mortise cavity, while
feeding the sensor and solenoid wires into the mortise
cavity and out the sensor & solenoid wire hole to the
inside of the door.
Note: The field wire harness should be routed above and
behind the mortise case (depending on where the hole
through the door meets the mortise cavity).
3 Make sure there are 3″ to 4″ of slack in the field wire
harness to allow access to the control electronics
circuit board in the inside trim.
4 Secure the mortise case with the case mounting
screws.
10 Install mounting plates
1 Insert the outside mounting plate through the door
and mortise case.
2 Position the inside mounting plate opposite the
outside mounting plate and screw them securely in
place.
Caution: Do not overtighten the mounting plate
screws. Overtightening may compress the mortise
cavity and bind the locking mechanism.
Figure 9 Installing the mortise case
Inside of door
Field wire harness
Inside
trim
Sensor & solenoid
wire hole and wires
Mortise
case
Mortise cavity
Figure 10 Installing the mounting plates
Outside of door
Outside
mounting plate
Inside
mounting
plate