Service and Maintenance for Cylindrical Locks
W Series Service Manual 5–29
3. Connect the door status sensor connector and shorting connector to
the sensor and solenoid wire harness.
4. Reinstall the upper and lower escutcheon screws on the inside
escutcheon.
5. Reinstall the inside lever/knob. See Task H. To reinstall the inside
and outside levers/knobs: on page 5–16.
6. Reinstall the access door. See Task J. To reinstall the access door:
on page 5–18.
Wire connection Color No. of wires No. of pins
Shorting connection Purple 2 2
Door status sensor White 2 2