IDH Max Locks Functions and Parts
W Series Service Manual 2–3
NEL–Electrically Locked–Fail Safe NEU–Electrically Unlocked–Fail Secure
Latchbolt operated by:
■ inside lever/knob
■ outside lever/knob when
electric power is removed
from the solenoid
Outside lever/knob locked
by:
■ applying 12 VDC to the
solenoid; remains locked only
while power continues to be
applied
Outside lever/knob unlocked
by:
■ removing 12 VDC from the
solenoid
Inside lever/knob is always
unlocked
Latchbolt operated by:
■ inside lever/knob
■ outside lever/knob when
electric power is applied to
the solenoid
Outside lever/knob locked
by:
■ removing 12 VDC from the
solenoid
Outside lever/knob unlocked
by:
■ applying 12 VDC to the
solenoid; remains unlocked
only while power continues
to be applied
Inside lever/knob is always
unlocked