Vue de la page 144
Additional Service and Maintenance for IDH Max Locks
W Series Service Manual 6–5
7. Reinstall the core and throw member. For mortise instructions, see
Task H. To reinstall the core (EEL and EEU only): on page 4–23.
For cylindrical instructions, see Task I. To reinstall the core and
throw member: on page 5–17.
8. Making sure that the access door does not pinch any wires, insert
the tabs of the access door into its mating slots and swing the door
closed. Use the appropriate bit driver to secure the access door with
the security screw. Tighten firmly.
Removing and
reinstalling the field
wire harness
Removing the field wire harness
1. Remove the core and throw member. For mortise instructions, see
Task A. To remove the core: on page 4–3. For cylindrical
instructions, see Task A. To remove the core and throw member:
on page 5–3.
2. Remove the inside and outside knobs/levers. For mortise
instructions, see Task B. To remove the inside and outside
levers/knobs: on page 4–4. For cylindrical instructions,
see Task B1. To remove the keyed lever/knob: on page 5–3.
3. Use the appropriate bit driver to remove the security screw from the
access door. Open the access door and remove it from the inside
escutcheon.
4. Loosen the inside escutcheon and disconnect the connections. For
mortise instructions, see Task D. To disconnect the connections
and remove the outside escutcheon: on page 4–6. For cylindrical
instructions, see Task D. To disconnect the connections and
remove the outside escutcheon: on page 5–4.
5. For mortise locks, perform the following steps:
Remove the cylinder and mortise case faceplate. See Task E. To
remove the mortise case faceplate and cylinder: on page 4–10.
Remove the mounting plates. See Task F. To remove the
mounting plates: on page 4–11.
Remove the mortise case. See Task G. To remove the mortise
case: on page 4–11.
6. Remove the inside escutcheon from the door. For mortise
instructions, see Task H. To remove the inside escutcheon: on
page 4–12. For cylindrical instructions, see Task H. To remove the
inside escutcheon: on page 5–7.
7. Place the inside escutcheon on a flat surface.
8. Use a #1 Phillips head screwdriver to unscrew the lower-right
circuit board screw and remove the field wire harness strain relief.
Be careful not to touch the circuit board with the screwdriver and
not to strip the screw.