Installation Instructions for 34HW–35HW IDH Max Mortise Locks
BEST ACCESS SYSTEMS
Indianapolis, Indiana
7
Installation Instructions for 34HW–35HW IDH Max Mortise Locks
Preparing the door and door jamb
5 Drill hole for field wire harness
Caution 1: Check with your local fire marshal
before drilling a fire-rated door. Drilling through
a fire-rated door may void the fire label.
Caution 2: Be careful to drill straight through the
door, making sure the drill does not break
through the face of the door.
1 Remove the hinge nearest to the mortise cavity.
2 Using a three (3) to four (4) foot drill bit, drill a 3/8
diameter hole through the upper back of the mortise
cavity to the center of the nearest hinge mortise.
Note: It may be easier to drill halfway from each side of
the door.
6 Prepare for wire transfer hinge and run
field wiring
1 Drill a wire access hole through the frame side of the
hinge mortise.
2 Drill holes (or pockets) for splice connectors in the
frame and door. Refer to the hinge manufacturer’s
specifications for the hole location.
3 De-burr the holes to prevent damage to the hinge
leads.
4 Run the power field wiring from the location for the
lock’s power supply to the location for the wire
transfer hinge.
5 Run the communication field wiring from the location
for the panel interface module to the location for the
wire transfer hinge.
Note: For an overview of the system, see the figure on
page 1. For specifications for power and communication
field wiring, see Components checklist, on page 2.
6 Pull the field wiring down the wall and through the
access hole in the frame.
Figure 5 Drilling the hole for the field wire harness
Hinge mortise
Upper back of
mortise cavity
Hole through
door
Inside of door
Figure 6 Preparing for the wire transfer hinge
Holes for splice
connectors
Door frame Door
Field wiring
(2 power &
2 communication)
Vue de la page 170