
12
ELECTROMECHANICAL LOCKS
Temperature control module
Features
• Stainless steel flexible conduit
• Includes end caps and wire protectors
• Easily installed
• No wire splicing required
Specifications
Conduit outside dia.: 0.340"
Conduit inside dia.: 0.240"
Conduit length: 15"
To order specify: 8WDTL
8WBU-1-A / 8WBU-1-N
8WBU-1-A
Standard plate
8WBU-1-N
Narrow plate
ELECTRIFIED ACCESSORIES
8WBU-1-A,N
Features
• All circuitry completely sealed
• Wire leads for easy installation
• Through hole mounting
• Usable on other manufacturer’s 24 VDC locksets
Specifications
Wire leads: 18 AWG stranded vinyl insulated
wire approx. 6" in length
Voltage input: 24 volts AC/DC
Voltage output: 24 volts DC minimum at one (1)
amp max. load for approx. one (1)
second, then 15 to 17 VDC
regulated output until input voltage
is interrupted.
Output
protection: Short circuit current limiting set at
one (1) amp; output reverse hookup
protection for internal circuitry only.
Operating temp: -4 to 158°F (-20 to 70°C)
Size: 2" x 2
1
/
8
" x 1
3
/
8
"
To order specify: 8WTCM
Door transfer loop
Function/Application
Provides a means to transfer power from the door frame to
the door stile. Allows the door to swing a full 180 degrees.
8WTCM
8WDTL
8WDTL
Function/Application
A temperature control module (TCM) reduces the amount
of current flow to a lockset one second after energizing,
thereby lowering the temperature of the lockset trim. A
TCM may be needed on an electrified mortise or electrified
cylindrical lockset if energized for long periods of time.
The TCM is not used with any IDH-Max function. The TCM
Must Be ordered separately for EWEU, WWEU, YEU
functions, but is automatically included with 34H–37H
EWEL, WWEL, YEL functions.
8WTCM
Function/Application
Normally open push-button switch provides momentary
switch closure when pressed. Typically used to
momentarily energize electrified locks or strikes or used
as a request-to-exit switch on access control systems.
Features
•
Positive “snap” feedback
• Industrial-grade switch designed for rugged control
applications
• Factory assembled with trimplate
• Standard or narrow plate available
• 1
3
/
16
" dia. mushroom head—red in color
Specifications
Electrical rating: 28VDC or 115 VAC, 10A resistive,
5A inductive, 3A lamp load (see terminology on the
back cover)
Switch type: SPST-NO-DB, FORM-X contacts, 25,000
cycls at full load, 50,000 cycles mechanical life
Mounting hole:
5
/
8
" (.625) dia.
Switch dim.: 1.187 dia.x 1.528 overall length
Std. wall plate: 2
3
/
4
" x 4
1
/
2
"
Narrow wall plate: 1
1
/
2
" x 4
1
/
2
"
Material/finish: Satin stainless steel
Wire leads: Two 6" long 20 AWG insullated wire
leads
To order specify:
8WBU-1-A standard plate
8WBU-1-N narrow plate
Commentaires sur ces manuels